pdf datasheet site - dataSheet39.com


AD823AR PDF Datasheet Search Results

No Part number Description ( Function ) Manufacturers PDF
9 AD823
Dual/ 16 MHz/ Rail-to-Rail FET Input Amplifier

Data Sheet FEATURES Single-supply operation Output swings rail-to-rail Input voltage range extends below ground Single-supply capability from 3 V to 36 V High load drive Capacitive load drive of 500 pF, G = +1 Output current of 15 mA, 0.5 V from supplies Excellent ac performance on 2.6 mA/amplifier −3 dB bandwidth of 16 MHz, G = +1 350 ns settling time to 0.01% (2 V step) Sle

Analog Devices
Analog Devices
pdf
8 AD8230
Precision Instrumentation Amplifier

16 V Rail-to-Rail, Zero-Drift, Precision Instrumentation Amplifier AD8230 FEATURES Resistor programmable gain range: 101 to 1000 Supply voltage range: ±4 V to ±8 V Rail-to-rail input and output Maintains performance over −40°C to +125°C Excellent ac and dc performance 110 dB minimum CMR @ 60 Hz, G = 10 to 1000 10 μV maximum offset voltage (RTI, ±5 V operation) 50 nV/°

Analog Devices
Analog Devices
pdf
7 AD8231
Digital Programmable Instrumentation Amplifier

Data Sheet Zero Drift, Digitally Programmable Instrumentation Amplifier AD8231 FEATURES Digitally/pin-programmable gain G = 1, 2, 4, 8, 16, 32, 64, or 128 Specified from −40°C to +125°C 50 nV/°C maximum input offset drift 10 ppm/°C maximum gain drift Excellent dc performance 80 dB minimum CMR, G = 1 15 μV maximum input offset voltage 500 pA maximum bias current 0.7 μV

Analog Devices
Analog Devices
pdf
6 AD8232
Heart Rate Monitor Front End

Data Sheet FEATURES Single-Lead, Heart Rate Monitor Front End AD8232 FUNCTIONAL BLOCK DIAGRAM 20 19 18 17 16 Fully integrated single-lead ECG front end Low supply current: 170 µA (typical) Common-mode rejection ratio: 80 dB (dc to 60 Hz) Two or three electrode configurations High signal gain (G = 100) with dc blocking capabilities 2-pole adjustable high-pass filter Accepts u

Analog Devices
Analog Devices
pdf
5 AD8233
Heart Rate Monitor

Data Sheet 50 μA, 2 mm × 1.7 mm WLCSP, Low Noise, Heart Rate Monitor for Wearable Products AD8233 FEATURES Fully integrated, single-lead electrocardiogram (ECG) front end Low quiescent supply current: 50 μA (typical) Leads on/off detection while in shutdown (<1 μA) Common-mode rejection ratio: 80 dB (dc to 60 Hz) 2 or 3 electrode configurations High signal gain (G = 100)

Analog Devices
Analog Devices
pdf
4 AD8235
Micropower Instrumentation Amplifier

Data Sheet 40 μA Micropower Instrumentation Amplifier in WLCSP Package AD8235 FEATURES Low power 40 μA maximum supply current 6 nA shutdown current Low input currents 50 pA input bias current 25 pA input offset current High Common Mode Rejection Ratio (CMRR) 110 dB CMRR , G = 100 Space saving WLCSP package Zero input crossover distortion Versatile Rail-to-rail input and out

Analog Devices
Analog Devices
pdf