VPP10-500 Datasheet PDF - TRIAD
Part Number | VPP10-500 | |
Description | Power Transformer | |
Manufacturers | TRIAD | |
Logo | ||
There is a preview and VPP10-500 download ( pdf file ) link at the bottom of this page. Total 1 Pages |
Preview 1 page No Preview Available ! POWER TRANSFORMER
PC MOUNT:WORLD SERIES
VPP10–500
Electrical Specifications (@25C)
1. Maximum Power: 5.0VA
2. Input: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz
3. Output: Series1: 10.0V CT@ 0.5A; Parallel2: 5.0V @ 1.0A
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 30C TYP (45C MAX allowed)
6. Insulation Resistance: 100MΩ
7. Hipot: 4000VAC between primary to secondary and windings to core.
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds
UL flammability requirements.
Safety:
Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required.
World Series Transformers are designed and manufactured to meet the following agency approvals:
Agency File:
UL: File E53148, UL 5085-1 and 2 (formerly UL 506), General Purpose.
UL: File E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3.
CSA: File LR 221330. C22.2 NO. 66, General Purpose.
TUV: File R72103639, EN 60950, (IEC950) information Technology Equipment.
A. Dimensions:
Units: In inches
ABCDE FGH
1.062 1.375 0.187 0.200 0.400
B. PIN DIM. : 0.025 SQ
C. WT Lbs. : 0.37
D. Mounting Holes: 0.112 dia. x 2.0
1.312
1.625
1.000
Connections3:
Input: Series – Pin 1 to Pin 6, Jumper Pin 4 to Pin 3
Parallel – Pin 1 to Pin 6, Jumper Pin 1 to Pin 4 and Pin 3 to Pin 6
Output: Series – Pin 7 to Pin 12, Jumper Pin 9 to Pin 10
Parallel – Pin 7 to Pin 12, Jumper Pin 7 to Pin 10 and Pin 9 to Pin 12
17
3R
9
c
R
US
4 10
6 12
A
BC
D
E
D
F
G
RoHS Compliance: As of manufacturing date February 2005, all standard products
meet the requirements of 2011/65/EU, known as the RoHS initiative.
H
6
12
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for
the most current version.
4
3
10
9
1 Inherently limited. No fusing required. Class 2 not wet, Class 3 wet.
2 Inherently limited. No fusing required. Class 2.
3 Primary and secondary windings are designed to be connected in series or parallel. Winding are not
intended to be used independently.
1
SCHEMATIC
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013
7
|
|
Part DetailsOn this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for VPP10-500 electronic component. |
Information | Total 1 Pages | |
Link URL | [ Copy URL to Clipboard ] | |
Download | [ VPP10-500.PDF Datasheet ] |
Share Link :
Electronic Components Distributor
An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists. |
SparkFun Electronics | Allied Electronics | DigiKey Electronics | Arrow Electronics |
Mouser Electronics | Adafruit | Newark | Chip One Stop |
Featured Datasheets
Part Number | Description | MFRS |
VPP10-500 | The function is Power Transformer. TRIAD | |
Semiconductors commonly used in industry:
1N4148 |  
BAW56 |
1N5400 |
NE555 | | ||
Quick jump to:
VPP1
1N4
2N2
2SA
2SC
74H
BC
HCF
IRF
KA |