DataSheet.es    


PDF BL6533 Data sheet ( Hoja de datos )

Número de pieza BL6533
Descripción Single Phase / LCD / Energy Meter IC
Fabricantes BELLING 
Logotipo BELLING Logotipo



Hay una vista previa y un enlace de descarga de BL6533 (archivo pdf) en la parte inferior de esta página.


Total 10 Páginas

No Preview Available ! BL6533 Hoja de datos, Descripción, Manual

BL6533
Single Phase, LCD, Energy Meter IC
FEATURES
1 High accuracy, less than 0.1% error over a
dynamic range of 500 : 1
2 Exactly measure the real power in the positive
orientation and negative orientation, calculate
the energy in the same orientation
3 18×4 bit RAM for display data storage
4 Single 5V supply
The BL6533 is a low cost, high accuracy, high
stability, simple peripheral circuit electrical energy
meter IC. The meter based on the BL6533 is intended
for using in single-phase, two-wire distribution
systems.
The BL6533 adopts the oversample technology
and digital signal processing technology. It can
exactly measure the real power in the positive
orientation and negative orientation and calculate the
energy in the same orientation.
BL6533 thinks over the stability of reading
error in the process of calibration.. An internal no-load
threshold ensures that the BL6533 does not exhibit
any creep when there is no load.
BL6533 System
http://www.belling.com.cn
-1-
Total 10 Pages
9/9/2009

1 page




BL6533 pdf
BL6533 Single Phase Energy Meter IC with LCD Driver
ABSOLUTE MAXIMUM RATINGS
(TA=25VDD=5.0V)
Parameter Symbol
Test Condition
1.Power
Current
2.LCD POWER
3.Input High
Voltage 1
Input Low
Voltage 1
4. Input High
Voltage 2
Input Low
Voltage 2
5. Analog Input
Pins
V1P,V1N
V2P
Maximum
Input Voltage
DC Input
Impedance
Input
Capacitance
6.dynamic
current
VDD
VLCD
VIH1
VIL1
VIH2
VIL2
VAIN
IDD
-
-
Input Pin
Input Pin
RES
RES
Pin6,7,
9
4MHz,No load
Min
Value
4.7
Typical
Value
-
Max
Value
5.5
2.7
0.7VDD
0
0.9VDD
0
-
-
-
-
-
5.5
VDD
0.3VDD
VDD
0.4VDD
Unit
V
V
V
V
V
V
±1 V
330 Kohm
6 10 pF
- 7 10 mA
TERMINOLOGY
1) Measurement Error
The error associated with the energy measurement made by the BL6533 is defined by the following
formula:
2) Nonlinear Error
The Nonlinear Error is defined by the following formula:
eNL%[(Error at X-Error at Ib) / (1+Error at Ib )]*100%
http://www.belling.com.cn
-5-
Total 10 Pages
9/9/2009

5 Page










PáginasTotal 10 Páginas
PDF Descargar[ Datasheet BL6533.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
BL6533Single Phase / LCD / Energy Meter ICBELLING
BELLING

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar