CC3-E Specifications
5
Input
Output
Function
Environment
Isolation
Standards
Mechanical
Nominal Voltage
Voltage Range
Efficiency (typ)
(*1)
Current (typ)
(*1)
Nominal Voltage
Maximum Current
Maximum Power
(*2)
Maximum Line Regulation(Within input voltage range)
Maximum Load Regulation (0-100% load) (*3)
Temperature Coefficient
(Ambient temperature -40 to +50 )
Max Power Total Regulation (max)(*4)
Maximum Ripple & Noise (typ/max) (*5)
Voltage Adjustable Range
Over Current Protection
(*6)
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation Resistance
Safety Standards
Weight (typ)
Size (W x H x D)
V
V
A
VDC
A
mV
mV
mVp-p
VDC
RH
RH
g
mm
73 77
0.723
0.779
3.3 5
0.800
0.600
2.64
20
40
DC5.0
DC4.5-9.0
82
0.732
12 15
0.250
0.200
3
40
100
12
0.125
81
0.741
15
0.100
80
600
80mV
200mV
300mV
35
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Available
Not available
Available
-40 to +85
-40 to +85
5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
4.5
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25 C.
(*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25 C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
Input
Output
Function
Environment
Isolation
Standards
Mechanical
Nominal Voltage
Voltage Range
Efficiency (typ)
(*1)
Current (typ)
(*1)
Nominal Voltage
Maximum Current
Maximum Power
(*2)
Maximum Line Regulation(Within input voltage range)
Maximum Load Regulation (0-100% load) (*3)
Temperature Coefficient
(Ambient temperature -40 to +50 )
Max Power Total Regulation (max)(*4)
Maximum Ripple & Noise (typ/max) (*5)
Voltage Adjustable Range
Over Current Protection
(*6)
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation Resistance
Safety Standards
Weight (typ)
Size (W x H x D)
V
V
A
VDC
A
W
mV
mV
mVp-p
VDC
RH
RH
g
mm
74 79
0.297
0.316
3.3 5
0.800
0.600
2.64
20
40
DC12
DC9.0-18
82
0.305
12 15
0.250
0.200
3
40
100
12
0.125
81
0.309
15
0.100
80
600
80mV
200mV
300mV
35
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Available
Not available
Available
-40 to +85
-40 to +85
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
4.5
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25 C.
(*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25 C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.


line_dark_gray

Preview 5 Page


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for CC10-E electronic component.


Information Total 25 Pages
Link URL [ Copy URL to Clipboard ]
Download [ CC10-E.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
CC10-0503Sx-EThe function is Insulation type DC-DC converter. TDK-LambdsTDK-Lambds
CC10-0505Sx-EThe function is Insulation type DC-DC converter. TDK-LambdsTDK-Lambds
CC10-0512Dx-EThe function is Insulation type DC-DC converter. TDK-LambdsTDK-Lambds

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

CC10     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search