Preview 1 page

No Preview Available ! SHT21 datasheet, circuit

Datasheet SHT21
Humidity and Temperature Sensor IC
Fully calibrated
Digital output, I2C interface
Low power consumption
Excellent long-term stability
DFN type package reflow solderable
Product Summary
The SHT21 humidity and temperature sensor of Sensirion
has become an industry standard in terms of form factor
and intelligence: Embedded in a reflow solderable Dual
Flat No leads (DFN) package of 3 x 3mm foot print and
1.1mm height it provides calibrated, linearized sensor
signals in digital, I2C format.
The SHT2x sensors contain a capacitive type humidity
sensor, a band gap temperature sensor and specialized
analog and digital integrated circuit all on a single
CMOSens® chip. This yields in an unmatched sensor
performance in terms of accuracy and stability as well as
minimal power consumption.
Every sensor is individually calibrated and tested. Lot
identification is printed on the sensor and an electronic
identification code is stored on the chip which can be
read out by command. Furthermore, the resolution of
SHT2x can be changed by command (8/12bit up to
12/14bit for RH/T) and a checksum helps to improve
communication reliability.
With this set of features and the proven reliability and
long-term stability, the SHT2x sensors offer an
outstanding performance-to-price ratio. For testing SHT2x
two evaluation kits EK-H4 and EK-H5 are available.
Dimensions
3.0
0.3 typ
1.4 max
2.2
0.4 0.3
1.1
Bottom
View
NC VDD SCL
Sensor Chip
SHT21 features a generation 4C CMOSens® chip.
Besides the capacitive relative humidity sensor and the
band gap temperature sensor, the chip contains an
amplifier, A/D converter, OTP memory and a digital
processing unit.
Material Contents
While the sensor itself is made of Silicon the sensors’
housing consists of a plated Cu lead-frame and green
epoxy-based mold compound. The device is fully RoHS
and WEEE compliant, e.g. free of Pb, Cd and Hg.
2.4
1.0 1.0
NC VSS SDA
Figure 1: Drawing of SHT21 sensor package, dimensions are
given in mm (1mm = 0.039inch), tolerances are ±0.1mm. The
die pad (center pad) is internally connected to VSS. The NC
pads must be left floating. VSS = GND, SDA = DATA.
Numbering of E/O pads starts at lower right corner (indicated by
notch in die pad) and goes clockwise (compare Table 2).
Additional Information and Evaluation Kits
Additional information such as Application Notes is
available from the web page www.sensirion.com/sht21.
For more information please contact Sensirion via
info@sensirion.com.
For SHT2x two Evaluation Kits are available: EK-H4, a
four-channel device with Viewer Software, that also serves
for data-logging, and a simple EK-H5 directly connecting
one sensor via USB port to a computer.
www.sensirion.com
Version 4 May 2014
1/14

line_dark_gray
SHT21 equivalent
Datasheet SHT21
recommended to further process the sensors within 1 year
after date of delivery.
It is of great importance to understand that a humidity
sensor is not a normal electronic component and needs to
be handled with care. Chemical vapors at high
concentration in combination with long exposure times
may offset the sensor reading.
For this reason it is recommended to store the sensors in
original packaging including the sealed ESD bag at
following conditions: Temperature shall be in the range of
10°C 50°C and humidity at 20 60%RH (sensors that
are not stored in ESD bags). For sensors that have been
removed from the original packaging we recommend to
store them in ESD bags made of metal-in PE-HD12.
In manufacturing and transport the sensors shall be
prevented of high concentration of chemical solvents and
long exposure times. Out-gassing of glues, adhesive tapes
and stickers or out-gassing packaging material such as
bubble foils, foams, etc. shall be avoided. Manufacturing
area shall be well ventilated.
For more detailed information please consult the
document “Handling Instructions” or contact Sensirion.
2.3 Temperature Effects
Relative humidity reading strongly depends on
temperature. Therefore, it is essential to keep humidity
sensors at the same temperature as the air of which the
relative humidity is to be measured. In case of testing or
qualification the reference sensor and test sensor must
show equal temperature to allow for comparing humidity
readings.
If the sensor shares a PCB with electronic components
that produce heat it should be mounted in a way that
prevents heat transfer or keeps it as low as possible.
Measures to reduce heat transfer can be ventilation,
reduction of copper layers between the sensor and the
rest of the PCB or milling a slit into the PCB around the
sensor see Figure 10.
Furthermore, there are self-heating effects in case the
measurement frequency is too high. To keep self-heating
below 0.1°C, SHT2x should not be active for more than
10% of the time e.g. maximum two measurements per
second at 12bit accuracy shall be made.
Figure 10 Top view of example of mounted SHT2x with slits
milled into PCB to minimize heat transfer.
2.4 Light
The SHT2x is not light sensitive. Prolonged direct
exposure to sunshine or strong UV radiation may age the
sensor.
2.5 Materials Used for Sealing / Mounting
Many materials absorb humidity and will act as a buffer
increasing response times and hysteresis. Materials in the
vicinity of the sensor must therefore be carefully chosen.
Recommended materials are: Any metals, LCP, POM
(Delrin), PTFE (Teflon), PEEK, PP, PB, PPS, PSU, PVDF,
PVF.
For sealing and gluing (use sparingly): Use high filled
epoxy for electronic packaging (e.g. glob top, underfill),
and Silicone. Out-gassing of these materials may also
contaminate the sensor (see Section 2.2). Therefore try to
add the sensor as a last manufacturing step to the
assembly, store the assembly well ventilated after
manufacturing or bake at >50°C for 24h to outgas
contaminants before packing.
2.6 Wiring Considerations and Signal Integrity
Carrying the SCL and SDA signal parallel and in close
proximity (e.g. in wires) for more than 10cm may result in
cross talk and loss of communication. This may be
resolved by routing VDD and/or VSS between the two
SDA signals and/or using shielded cables. Furthermore,
slowing down SCL frequency will possibly improve signal
integrity. Power supply pins (VDD, VSS) must be
decoupled with a 100nF capacitor see next Section.
12 For example, 3M antistatic bag, product “1910” with zipper.
www.sensirion.com
Version 4 May 2014
5/14


line_dark_gray

Preview 5 Page



Information Total 14 Pages
Link URL [ Copy URL to Clipboard ]
Download [ SHT21.PDF Datasheet ]


Share Link :

Electronic Components Distributor

SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Element14 Chip One Stop


Featured Datasheets

Part NumberDescriptionManufacturers
SHT20The function is Humidity and Temperature Sensor IC.Sensirion
Sensirion
SHT20PThe function is Humidity and Temperature Sensor IC.Sensirion
Sensirion
SHT20SThe function is Humidity and Temperature Sensor IC.Sensirion
Sensirion

Quick jump to:

SHT2  1N4  2N2  2SA  2SC  74H  ADC  BC  BF  BU  CXA  HCF  IRF  KA  KIA  LA  LM  MC  NE  ST  STK  TDA  TL  UA 


DataSheet39.com is an Online Datasheet PDF Search Site.
It offers a large amount of data sheet, You can free PDF files download.
The updated every day, always provide the best quality and speed.



keyword : SHT21 schematic, equivalent, pinout, replacement, circuit, manual

DataSheet39.com   |  2020   |  Privacy Policy |  Contact Us  | New  |  Search