DataSheet39.com

What is CUB5SNK0?

This electronic component, produced by the manufacturer "red lion", performs the same function as "MINIATURE ELECTRONIC 8-DIGIT DUAL COUNTER AND RATE INDICATOR".


CUB5SNK0 Datasheet PDF - red lion

Part Number CUB5SNK0
Description MINIATURE ELECTRONIC 8-DIGIT DUAL COUNTER AND RATE INDICATOR
Manufacturers red lion 
Logo red lion Logo 


There is a preview and CUB5SNK0 download ( pdf file ) link at the bottom of this page.





Total 16 Pages



Preview 1 page

No Preview Available ! CUB5SNK0 datasheet, circuit

Bulletin No. CUB5-K
Drawing No. LP0584
Released 02/13
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL CUB5 - MINIATURE ELECTRONIC 8-DIGIT DUAL
COUNTER AND RATE INDICATOR
C UR L US LISTED
IND. CONT. EQ.
51EB
LCD, REFLECTIVE OR GREEN/RED LED BACKLIGHTING
0.46" (11.7 mm) HIGH DIGITS
OPTIONAL SETPOINT OUTPUT CARD
OPTIONAL SERIAL COMMUNICATIONS CARD (RS232 or RS485)
OPTIONAL USB PROGRAMMING CARD
OPERATES FROM 9 TO 28 VDC POWER SOURCE
PROGRAMMABLE SCALING FOR COUNT AND RATE
BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL
QUADRATURE SENSING (UP TO 4 TIMES RESOLUTION)
BUILT-IN BATCH COUNTING CAPABILITY
DISPLAY COLOR CHANGE CAPABILITY AT SETPOINT OUTPUT
NEMA 4X/IP65 SEALED FRONT BEZEL
GENERAL DESCRIPTION
The CUB5 provides the user the ultimate in flexibility, from its complete user
programming to the optional setpoint control and communication capability.
The meter can be programmed as a single or dual counter with rate indication
capability. The display can be toggled either manually or automatically between
the selected displays.
The CUB5 display has 0.46" (11.7 mm) high digits. The LCD is available in
two versions, reflective (CUB5R000) and backlight (CUB5B000). The backlight
version is user selectable for green or red backlighting with variable display
intensity.
The counter is programmable for one of eight different count modes,
including bi-directional and quadrature. When programmed as a dual counter,
each counter has a separate scale factor and decimal points. In the counter/rate
indicator mode, each have their own scaling and decimal point read-outs in
different engineering units. The internal batch counter can be used to count
setpoint output activations.
The meter has two separate inputs which provide different functions
depending on which operating mode is selected. Input A accepts the signal for
the Count and/or Rate displays, while Input B accepts the signal for the Count
display or direction control. In the anti-coincidence mode, both inputs are
monitored simultaneously so that no counts are lost. The resulting display can
be chosen as the sum or difference of the two inputs. The Rate Indicator has
programmable low (minimum) and high (maximum) update times to provide
optimal display response at any input frequency. There is a programmable user
input that can be programmed to perform a variety of functions.
The capability of the CUB5 can be easily expanded with the addition of
option cards. Setpoint capability is field installable with the addition of the
single setpoint relay output card or the dual setpoint solid state output card.
Serial communications capability for RS232 or RS485 is added with a serial
option card.
The CUB5 can be powered from an optional Red Lion Micro-Line/Sensor
Power Supply (MLPS), which attaches directly to the back of a CUB5. The
MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the
unit and sensors.
COUNTER
The CUB5 receives incoming pulses and multiplies them by the Count Scale
Factor to obtain the desired reading for the count display. Input A accepts the
signal for the count and Input B is used for quadrature, dual counter, anti-
coincidence counting, or up/down control counting.
RATE
The rate indicator utilizes the signal at Input A to calculate the rate value
using a time interval method (1/tau). The unit counts on the negative edge of the
input pulses. After the programmed minimum update time elapses and the next
negative edge occurs, the unit calculates the input rate based on the number of
edges that occurred during the elapsed time. The input rate is then multiplied by
the rate scaling value to calculate the rate display.
At slower rates, averaging can be accomplished by programming the rate
minimum update time for the desired response. Extensive scaling capabilities
allow practically any desired reading at very slow count rates.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in this
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use this meter to directly command motors, valves, or other actuators
not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the meter.
CAUTION: Risk of Danger.
Read complete instructions prior to
installationand operation of the unit.
CAUTION: Risk of electric shock.
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.
.13 (3.3)
9876543.2 1.54(39.1)
SEL RST
2.95 (74.9)
.15 (3.8)
1.29 (32.8)
1.71
(43.4)
1
ON ECE
12 3 4
1.30
+.024
-.000
(33
+6
-0
)
2.68
+.025
-.000
(68
+8
-0
)

line_dark_gray
CUB5SNK0 equivalent
4.3 INPUT WIRING
CAUTION: Power common (PWR COMMON) is NOT isolated from input common (INP COMM). In order to preserve the safety of the meter
application, the power common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth
ground potential. If not, hazardous voltage may be present at the Signal or User Inputs and input common terminals. Appropriate considerations must
then be given to the potential of the input common with respect to earth ground; and the common of the plug-in cards with respect to input common.
Magnetic Pickup
Input A
AC Inputs From Tach Generators, Etc.
Input A
Two Wire Proximity, Current Source
Input A
ON
*
12 34
MAGNETIC PICKUP
PWR COMMON
Current Sinking Output
+9-28 VDC
Input A
ON
**
12 34
Resistor to Limit Current
to 2.5 mA MAX.
AC
PWR COMMON
+9-28 VDC
Current Sourcing Output
Input A
ON
**
12 34
2.2 k Ω
PWR COMMON
Interfacing With TTL
+9-28 VDC
Input A
ON
**
12 34
ON
NPN
O.C.
**
12 34
ON
PNP *
O.C.
12 34
+5 V
COMMON
PWR COMMON
+9-28 VDC
Switch or Isolated Transistor; Current Sink
Input A
PWR COMMON
+9-28 VDC
PWR COMMON
+9-28 VDC
Switch or Isolated Transistor; Current Source Current Sink Output; Quad/Direction
Input A
ON
**
12 34
ON
**
12 34
PWR COMMON
+9-28 VDC
PWR COMMON
Switch position is application dependent.
4.4 SETPOINT (OUTPUT) WIRING
SINGLE SETPOINT RELAY PLUG-IN CARD
COM
N.O.
N.C.
+9-28 VDC
ON
12 34
PWR COMMON
+9-28 VDC
Shaded areas not recommended for counting applications.
ELECTRICAL CONNECTIONS
COM N.O. N.C.
DUAL SETPOINT N-FET OPEN DRAIN PLUG-IN CARD
COM
OSNK1
OSNK2
ELECTRICAL CONNECTIONS
OSNK 1(2)
(30 V MAX.)
COM
Note: Output Common is not isolated from DC Power Common. Load must
be wired between OSNK terminal and V+ of the load supply.
4.5 SERIAL COMMUNICATION WIRING
SERIAL COMMUNICATIONS PLUG-IN CARD
4.6 USB PROGRAMMING
USB PROGRAMING PLUG-IN CARD
654321
65 4 3 2 1
RS485
RS232
RJ11 CONNECTOR PIN OUTS
5


line_dark_gray

Preview 5 Page


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for CUB5SNK0 electronic component.


Information Total 16 Pages
Link URL [ Copy URL to Clipboard ]
Download [ CUB5SNK0.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
CUB5SNK0The function is MINIATURE ELECTRONIC 8-DIGIT DUAL COUNTER AND RATE INDICATOR. red lionred lion

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

CUB5     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search