70W Single Output LED Power Supply
HLG-60H-C series
¡½ Features :
¡E Constant current design
¡E Universal AC input / Full range (up to 305VAC)
¡E Built-in active PFC function
¡E High efficiency up to 91%
¡E Protections: Short circuit / Over voltage / Over temperature
¡E Cooling by free air convection
¡E Output current adjustable through output cable or internal potentiometer
¡E IP67 / IP65 design for indoor or outdoor installations
¡E Three in one dimming function (1~10Vdc or 10V PWM signal or resistance)
¡E Suitable for dry / damp / wet locations
¡E 5 years warranty (Note.5)
(HLG-60H-C700 only)
F 110 M M SELV
IP65 IP67
(HLG-60H-C700 only)
HLG-60H-C350 A A : IP65 rated. Constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
SPECIFICATION
MODEL
HLG-60H-C350
HLG-60H-C700
OUTPUT
RATED CURRENT
CURRENT ACCURACY
350mA
¡Ó 5.0%
700mA
CONSTANT CURRENT REGION Note.6 100 ~ 200V
50 ~ 100V
RATED POWER
RIPPLE CURRENT
70W
¡Ó 5%
70W
RIPPLE & NOISE
Note.7 1Vp-p
0.5Vp-p
CURRENT ADJ. RANGE
LINE REGULATION
Can be adjusted by internal potentiometer A type only
210 ~ 350mA
¡Ó 1%
420 ~ 700mA
¡Ó 1%
SETUP, RISE TIME
1500ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC at full load
HOLD UP TIME (Typ.)
16ms at full load 230VAC / 115VAC
INPUT
VOLTAGE RANGE Note.2 90 ~ 305VAC 127VDC ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION Total harmonic distortion will be lower than 20% when output loading is 75% or higher
EFFICIENCY (Typ.)
91%
90.5%
AC CURRENT (Typ.)
0.69A / 115VAC 0.35A / 230VAC 0.29A / 277VAC
INRUSH CURRENT (Typ.) COLD START 70A / 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
PROTECTION
OVER TEMPERATURE
WORKING TEMP.
230 ~ 250V
120 ~ 140V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
85¢J¡Ó 10¢J (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
¢J-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
10 ~ 95% RH non-condensing
¢J-40 ~ +80 , 10 ~ 95% RH
¡Ó0.03%/¢J (0 ~ 50¢J )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.3 UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent, IP65 or IP67 approved
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
¢JI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
¡ÙCompliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
EMC IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level (surge L,N-FG: 4KV), criteria A
¢J338K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
171*61.5*36.8 mm (L*W*H)
NOTE
PACKING
0.73Kg; 20pcs/15.6Kg/0.9CUFT
¢J1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Derating may be needed under low input voltages. Please check the static characteristics for more details.
3. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1.
4. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
5. Refer to warranty statement.
6. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
7. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 2.2uf parallel capacitor.
File Name:HLG-60H-C-SPEC 2012-11-14
Free Datasheet http://www.Datasheet4U.com

line_dark_gray
HLG-60H-C700 equivalent
70W Single Output LED Power Supply
DIMMING OPERATION (for B-type only)
HLG-60H-C series
AC/L(Brown)
AC/N(Blue)
FG (Green/Yellow)
HLG-60H-C
+V(Red)
-V(Black)
DIM+(Blue)
DIM-(White)
¡° Built-in 3 in 1 dimming function, IP67 rated. Output constant current level can be adjusted through output cable by connecting a resistance or
1 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-.
¡° Please DO NOT connect "DIM-" to "-V".
¡° Reference resistance value for output current adjustment (Typical)
Resistance Single driver
10K£[ 20K£[ 30K£[ 40K£[ 50K£[ 60K£[ 70K£[ 80K£[ 90K£[ 100K£[
value
Multiple drivers
£[ £[ £[ £[ £[ £[ £[ £[ £[ £[(N=driver quantity for synchronized 10K /N 20K /N 30K /N 40K /N 50K /N 60K /N 70K /N 80K /N 90K /N 100K /N
dimming operation)
OPEN
-----
Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108%
¡° 1 ~ 10V dimming function for output current adjustment (Typical)
Dimming value
1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN
Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108%
¡° 10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz
Duty value
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN
Percentage of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108%
¡° Using the built-in dimming function on B-type model can't turn the lighting fixture totally dark. Please refer to the connection method below to
achieve 0% brightness of the lighting fixture connecting to the LED power supply unit.
¡° Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
Dimming connection diagram for turning the lighting fixture ON/OFF :
N FG L
Relay
Switch
Adjuster
0~100K Ohms resistance
1~10V DC Voltage
10V PWM Signal
Green/
Yellow
Brown
Blue
AC/L
AC/N
HLG-60H-C
B Type
DIM+
DIM-
V(-)
V(+)
Blue
White
Black
Red
LED Lighting Fixture
Using a switch and relay can turn ON/OFF the lighting fixture.
1.Output constant current level can be adjusted through output cable by connecting a resistance or 1~10Vdc or 10V PWM signal between DIM+ and DIM-.
2.The LED lighting fixture can be turned ON/OFF by the switch.
File Name:HLG-60H-C-SPEC 2012-11-14
Free Datasheet http://www.Datasheet4U.com


line_dark_gray

Preview 5 Page


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for HLG-60H-C700 electronic component.


Information Total 13 Pages
Link URL [ Copy URL to Clipboard ]
Download [ HLG-60H-C700.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
HLG-60H-C700The function is 70W Single Output LED Power Supply. Mean WellMean Well

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

HLG-     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search