DataSheet39.com

What is SWS600?

This electronic component, produced by the manufacturer "Lambda", performs the same function as "(SWS300 / SWS600) Single Output General Purpose Power Supplies".


SWS600 Datasheet PDF - Lambda

Part Number SWS600
Description (SWS300 / SWS600) Single Output General Purpose Power Supplies
Manufacturers Lambda 
Logo Lambda Logo 


There is a preview and SWS600 download ( pdf file ) link at the bottom of this page.





Total 2 Pages



Preview 1 page

No Preview Available ! SWS600 datasheet, circuit

SWS300/600 Series
Single Output General Purpose Power Supplies
Features
u Low Cost
u Active Power Factor Correction
u Universal Input (85 - 265VAC)
u Input Transient Protected IEC61000-4
u SEMI F47 Certified (208VAC Input)
u Global safety Approvals
u Level B EMI
Key Market Segments & Applications
Specifications
Model
SWS300
SWS600
Input Voltage range
(1) -
85 - 265VAC (47 - 63Hz) or 120 - 370VDC
Inrush Current (115 / 230VAC)
A
20 / 40 at 25°C, cold start
Power Factor
-
Meets EN61000-3-2
Input Current (100/200VAC)
A
3.6 / 1.8A
7.2 / 3.6A
Temperature Coefficient
-
<0.02%/°C
Overcurrent Protection
-
>105%, Constant current style
Overvoltage Protection
V
3.3V: 4.1-5.3V, 5V: 6.25-7.5V, 12V: 13.8-16.8V
15V: 19.3-24.2V, 24V: 30-34.8V, 36V: 41.4-50.4V, 48V: 60-69.6V
Overtemperature Protection
-
Yes, cycle AC to reset
Hold Up Time (Typ)
ms
20ms at 115/230VAC
Leakage Current (max)
mA
SWS300: 0.75mA , SWS600: 1.5mA
Remote Sense - None
Yes
Parallel Connection
-
None
Yes
Remote On/Off - None
Yes, >4.5V to shutdown
Power Fail Signal
-
None
Yes, open collector output
LED Indicator
-
Green LED = On
Operating Temperature
°C
-10 to +65°C (See table for derating - model specific)
Storage Temperature
°C
-30 to +85°C
Humidity (non-condensing)
-
30 - 90% RH operating, 10 - 95%RH non operating
Cooling
-
Internal fan
Withstand Voltage
- I/P to Grnd 2kVAC, I/P to O/P 3kVAC, O/P to Grnd 500VAC, O/P to CNT 100VAC for 1 min
Isolation Resistance
-
>100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating)
-
10 - 55Hz (sweep for 1 min)19.6m/s2 constant X, Y, Z 1 hour each plane)
Immunity
-
EN61000-4-2, -3, -4, -5, -6, -8, -11
Safety Agency Approvals
- UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark, SEMI F47 (208VAC)
Conducted & Radiated EMI
-
EN55011 / EN55022-B, FCC Class B
Recommended EMI Filter
-
MC1206
MC1210
Weight (Typ)
g 950
2000
Size (WxHxD)
in 2.05 x 4.01 x 7.8”
3.62 x 4.72 x 7.48”
Warranty
yrs
Two Years
Notes:(1) Derate linearly to 80% load from 115VAC to 85VAC input (derate to 90% load for SWS600-5, no derating SWS300, 600-3)
1-800-526-2324 • www.us.tdk-lambda.com/lp/
99 Disclaimer: us.tdk-lambda.com/lp/legal.htm
Free Datasheet http://www.datasheet-pdf.com/


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for SWS600 electronic component.


Information Total 2 Pages
Link URL [ Copy URL to Clipboard ]
Download [ SWS600.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
SWS600The function is (SWS300 / SWS600) Single Output General Purpose Power Supplies. LambdaLambda

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

SWS6     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search