Preview 1 page No Preview Available ! OWNER’S MANUAL
Self-Priming Centrifugal Pump
“DS3” Series
3621 1199 ASB
Installation/Operation/Parts
For further operating, installation,
or maintenance assistance:
Call 888-782-7483
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.sta-rite.COM
PH: 888-782-7483
© 2012 Pentair, Inc. All Rights Reserved.
S536 (11/08/12)
Free Datasheet http://www.datasheet4u.com/
|
|
Installation
5
HORIZONTAL PIPING FROM WELL TO PUMP
40 60 1. Never install a suction pipe that is smaller than the suction port of the
20 80
pump.100
2. To aid priming on well point installations, install a line check valve
as shown in Figure 2. Be sure check valve flow arrow points toward
pump.
Figure 3: Multiple Discharge
1909 0997 DS3
DISCHARGE PIPE SIZES
1. If increasing discharge pipe size, install reducer in pump discharge
port. Do not increase pipe size by stages.
2. When the pump is set away from the points of water use, the discharge
pipe size should be increased to reduce pressure losses caused by
friction.
• Up to 100’ run: Same size as pump discharge port.
• 100’ to 300’ run: Increase one pipe size.
• 300’ to 600’ run: Increase two pipe sizes.
LAWN SPRINKLING APPLICATION
This pump is designed for lawn sprinkling. It is designed to deliver plenty
of water at full sprinkler pressure. It can pump from a pond, cistern or well
points.
Pump discharge can be divided to supply two (2) or more sprinkler
systems. A suggested multiple disc harge to service is shown in Figure 3.
Do not use in a pressure tank or booster pump application.
Figure 4: Bolt Pump Down
40 60
20 80
100
3023 0997 DS3
PUMP INSTALLATION
NOTICE: Use only PTFE pipe thread sealant tape for making all threaded
connections to the pump itself. Do not use pipe joint compounds on
plastic pumps: they can react with the plastic in the pump components.
Make sure that all pipe joints in the suction pipe are air tight as well as
water tight. If the suction pipe can suck air, the pump will not be able to
pull water from the well.
1. Bolt pump to solid, level foundation.
2. Support all piping connected to the pump.
3. Wrap 1-1/2 to two layers of PTFE pipe thread sealant tape clockwise
(as you face end of pipe) on all male threads being attached to pump.
4. Tighten joints hand tight plus 1-1/2 turns. Do not overtighten.
NOTICE: Install pump as close to well head as possible. Long piping runs
and many fittings create friction and reduce flow.
NOTICE: For long horizontal pipe runs, install a priming tee between
check valve and well head as shown in Figure 1. For driven point
installations, install a check valve as shown in Figure 2. Be sure check
valve flow arrow points toward pump.
Use schedule 80 or iron pipe. See “Well Pipe Installation” for more
information.
Figure 5: Independently Support All3024 0997 DS3
Piping Attached to Pump
Preview 5 Page |
Part DetailsOn this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for DS3HE3-01 electronic component. |
Information | Total 12 Pages | |
Link URL | [ Copy URL to Clipboard ] | |
Download | [ DS3HE3-01.PDF Datasheet ] |
Share Link :
Electronic Components Distributor
An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists. |
SparkFun Electronics | Allied Electronics | DigiKey Electronics | Arrow Electronics |
Mouser Electronics | Adafruit | Newark | Chip One Stop |
Featured Datasheets
Part Number | Description | MFRS |
DS3HE3-01 | The function is Self-Priming Centrifugal Pump. Pentair | |
Semiconductors commonly used in industry:
1N4148 |  
BAW56 |
1N5400 |
NE555 | | ||
Quick jump to:
DS3H
1N4
2N2
2SA
2SC
74H
BC
HCF
IRF
KA |