No Preview Available ! ICR18650-30A Hoja de datos, Descripción, Manual

www.DataSheet4U.net
Spec. No.
SAMSUNG SDI Confidential Proprietary.
ICR18650-30A Version No.
0.0
SPECIFICATION OF PRODUCT
for Lithium-ion Rechargeable Cell
Model : ICR18650-30A
November, 2007
Samsung SDI Co.,Ltd.
Mobile Energy Division

1 page




ICR18650-30A pdf
www.DataSheet4U.net
Spec. No.
SAMSUNG SDI Confidential Proprietary.
ICR18650-30A Version No.
0.0
0.05C cut-off and the discharge (discharge current 1500mA) with 2.75 V cut-off.
Capacity after 299cycles and plus 1 day, measured under the same condition
in 7.2
Capacity 2030mAh(70% of the capacity at 25)
7.9 Storage Characteristics
Capacity after storage for 30days at 25from the standard charge,
measured with discharge current 1500mA with 2.75V cut-off at 25.
Capacity retention(after the storage) 2320mAh (80% of the capacity at 25)
7.10 Status of the cell as of ex-factory
The cell should be shipped in 50% charged state. In this case, OCV is from 3.65V to
3.85V.
8. Mechanical Characteristics
8.1 Drop Test
Test method: Cell(as of shipment or full charged) drop onto the oak-board
(thickness: 30mm) from 1.5m height at a random direction 6 times.
Criteria: No leakage
8.2 Vibration Test
Test method: Cell(as of shipment) is vibrated along 2 mutually
perpendicular axes with total excursion of 1.6mm and with
frequency cycling between 10Hz and 55Hz by 1Hz/min.
Criteria: No leakage
9. Safety
9.1 Overcharge Test
Test method: To charge the standard charged cell with 12V and 2.8A at 25
for 2.5 hours.
Criteria: No fire, and no explosion.
9.2 External Short-circuit Test
Test method: To short-circuit the standard charged cell by connecting positive and
negative terminal by less than 50mΩ wire for 3hours.
Criteria: No fire, and no explosion.
9.3 Reverse Charge Test
Test method: To charge the standard charged cell with charge current 2.8A
By –12V for 2.5 hours.
Criteria: No fire, and no explosion.
9.4 Heating Test
Test method: To heat up the standard charged cell at heating rate 5per minute up to
4 Mobile Energy Business Team

5 Page





ICR18650-30A arduino
www.DataSheet4U.net
Spec. No.
SAMSUNG SDI Confidential Proprietary.
ICR18650-30A Version No.
0.0
and high temperature components.
6.2.2 Otherwise, it may cause loss of characteristics.
6.3 Mechanical shock protection of the battery
6.3.1 The battery should equip with appropriate shock absorbers in order to
minimize shock.
6.3.2 Otherwise, it may cause shape distortion, leakage, heat generation
and/or rupture.
6.4 Short-circuit protection of the cell
6.4.1 The cell equips with an insulating sleeve to protect short-circuit which
may occur during transportation, battery assembly and /or system
operation.
6.4.2 If the cell sleeve is damaged by some cause such as outside impact,
it may cause short-circuit with some wiring inside the battery.
6.5 Connection between the battery and charger/system
6.5.1 The battery should be designed to be connected only to the specified
charger and system.
6.5.2 A reverse connection of the battery, even in the specified system,
should be avoided by employing special battery design such as
a special terminals.
7. Battery Pack Assembly
7.1 Prohibition of usage of damaged cell
7.1.1 The cell should be inspected visually before battery assembly.
7.1.2 The cell should not be used if sleeve-damage, can-distorsion and/or
electrolyte-smell is detected.
7.2 Terminals handling
7.2.1 Excessive force on the negative terminal should be avoided when
external lead is welled.
7.3 Transportation
7.3.1 If the cell is necessary to transported to order place, such as the
battery manufacturer, careful precautions should be taken to avoid
damage of cell.
8. Others
8.1 Disassembly
8.1.1 The cell should not be dismantled from the battery pack.
8.1.2 Internal short-circuit caused by disassembly may lead to heat generation
and/or venting.
8.1.3 When the electrolyte is coming in contact with the skin or eyes,
flush immediately with fresh water and seek medical advice.
10 Mobile Energy Business Team

11 Page







PáginasTotal 14 Páginas
PDF Descargar[ Datasheet ICR18650-30A.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
ICR18650-30Afor Lithium-ion Rechargeable CellSamsung
Samsung
ICR18650-30BLithium-ion Rechargeable CellSamsung
Samsung

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,