DataSheet39.com

What is BE5982?

This electronic component, produced by the manufacturer "ETC", performs the same function as "Emergency Stop Module".


BE5982 Datasheet PDF - ETC

Part Number BE5982
Description Emergency Stop Module
Manufacturers ETC 
Logo ETC Logo 


There is a preview and BE5982 download ( pdf file ) link at the bottom of this page.





Total 2 Pages



Preview 1 page

No Preview Available ! BE5982 datasheet, circuit

Safety technique
Emergency stop module BE 5982
safemaster
· According to EU Directive for machines 98/37/EG
· According to EN 60 204-1, DIN VDE 0113 part 1 (11.98)
· Safety category 4 according to DIN EN 954-1
· Output: 2 NO contacts for AC 250 V
· Single-channel emergency stop circuit
· LED indication for channels 1 / 2 and operating state
· Short circuit protection
· Wire connection: also 2 x 1,5 mm2 stranded ferruled (isolated),
DIN 46 228-4 or
2 x 2,5 mm2 stranded ferruled DIN 46 228-1/-2/-3
· Width 22,5 mm
www.DataSheet4U.com
Function diagram
Approvals and marking
Pushbutton
On
Emergency
stop (Off)
K1
K2
M7218
Block diagram
A1(+)
Y1 Y2
PTC
K1
K2
K1
K2
Mains K1/K2 K1
K2
13 23
K1
K2
A2(-)
M6760_a
Circuit diagram
A1 13 23 24
A1 Y1
13
K1
K2
A2 Y2
14
14 Y1 Y2 A2
23
24
M7384_a
14 24
ET
Application
· Protection of persons and machines
· Emergency stop circuits on machines
Indication
LED power supply:
LED K1/K2:
on when operating voltage present
on when output relays K1, K2 are
energized
Notes
When using the E-stop module with "automatic start" mode, the automatic
restart (according to EN 60 204-1 part 9.2.5.4.2 and 10.8.3) has to be
inhibited by the machine control.
Technical data
Input
Nominal voltage UN:
Voltage range
at 10 % residual ripple:
at 48 % residual ripple:
Nominal consumption:
Control voltage Y1:
Control current:
Recovery time:
DC 24 V
DC 0,9 ... 1,1 UN
DC 0,8 ... 1,1 UN
approx. 1,6 W
DC 24 V
typ. DC 45 mA
0,5 s
Output
Contacts
BE 5982.02:
Response time:
Release time:
Contact type:
Output rated voltage:
Thermal current Ith:
Switching capacity
to AC 15:
Electrical life
to AC 15 at 2 A, AC 230 V:
Permissible switching
frequency:
Short ciruit strength
max. fuse rating:
Mechanical life:
2 NO contacts
max. 100 ms
max. 35 ms
Relay, positively driven
AC 250 V
see continuous limit curve
(max. 6 A in one contact path)
5 A / AC 230 V
for NO contact
2 A / AC 230 V
for NC contact
EN 60 947-5-1
EN 60 947-5-1
105 switching cycles EN 60 947-5-1
600 switching cycles / h
4 A gL
EN 60 947-5-1
10 x 106 switching cyles
All technical data in this list relate to the state at the moment of edition. We reserve the right
for technical improvements and changes at any time.
1
BE 5982 / 30.10.01 d


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for BE5982 electronic component.


Information Total 2 Pages
Link URL [ Copy URL to Clipboard ]
Download [ BE5982.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
BE5982The function is Emergency Stop Module. ETCETC
BE5982.02The function is Emergency Stop Relay. ETCETC

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

BE59     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search