DataSheet39.com

What is CT0.4-P?

This electronic component, produced by the manufacturer "LEM", performs the same function as "(CT0.1-P - CT0.4-P) Current Transducers".


CT0.4-P Datasheet PDF - LEM

Part Number CT0.4-P
Description (CT0.1-P - CT0.4-P) Current Transducers
Manufacturers LEM 
Logo LEM Logo 


There is a preview and CT0.4-P download ( pdf file ) link at the bottom of this page.





Total 3 Pages



Preview 1 page

No Preview Available ! CT0.4-P datasheet, circuit

Current Transducers CT 0.1 .. 0.4-P
For the electronic measurement of small currents: AC,DC, mixed,
with a galvanic isolation between the primary circuit and the
secondary circuit.
IPN = ± 100..400 mA
VOUT = ± 5 V
Electrical data
Primary nominal
current rms
IPN (mA)
100
200
400
Primary current,
measuring range
IPM (mA)
± 180
± 360
± 720
Type
CT 0.1-P
CT 0.2-P
CT 0.4-P
VC
I
C
RIS
V
OUT
ROUT
R
L
CL
Supply voltage (± 5 %)
Current consumption
Isolation resistance @ 500 VDC
Output
voltage
(Analog)
@
±
I
PN,
R=
L
10k,
T =25°C
A
Output internal resistance
Load resistance
Capacitive loading
RoHS since
date code
46129
46054
46234
± 15
± 35
> 500
±5
< 51
10
5
V
mA
M
V
k
nF
Accuracy-Dynamic performance data
X
εL
TCVOUT
VOE
VOH
TCVOE
tr
BW
Accuracy (excluding offset) @ IPN, TA = 25°C, RL = 10k< ± 1 %of IPN
Linearity error (0 .. ± IPN)
< ± 0.5 %of IPN
Temperature coefficient of VOUT (of reading)
< ± 0.05 %/K
Eletrical offset voltage @ IP = 0, TA = 25°C
< ± 50
mV
Hysteresis offset voltage
@ IP = 0; after an excursion of 1 x IPN
<±2
@ IP = 0; after an excursion of 100 x IPN
< ± 20
Temperature coefficient of VOE @ -20..+85°C CT 0.1-P < ± 4
CT 0.2-P < ± 3
mV
mV
mV/K
mV/K
CT 0.4-P < ± 2 mV/K
Response time to 80% of IPN step
90% of I step
PN
Frequency bandwidth (- 3 dB)
20
ms
60
ms
CT 0.1-P DC .. 7000 Hz
CT 0.2-P DC .. 11000 Hz
CT 0.4-P DC .. 18000 Hz
General data
TA Ambient operating temperature
TS Ambient storage temperature
dCp Creepage distance
dCl Clearance distance
CTI Comparative tracking index (Group IIIa)
m Mass
Standards
- 20 .. + 85 °C
- 25 .. + 85 °C
> 5.5
mm
> 5.5
mm
> 220
25 g
EN 50178: 1997
Features
DC & AC earth leakage current
transducer using a flux-gate
principle
PCB mounting
±15V power supply
±5V
output
@
I
PN
Insulated plastic case recognized
according to UL94-V0.
Advantages
Small size
Bandwidth : DC .. up to 18kHz
Response time better than 60 ms
Cost effective, compact
alternative to classical RCDs
(Residual Current Device)
Applications
Earth leakage detection in
transformerless solar inverters
1st human contact protection of
PV arrays
Failure detection in power sources
Symmetrical fault detection
(e.g. after motor inverter)
Current leakage detection in
stacked DC sources
Single phase or three phase
differential current measurement up
to ±30A per wire (DC or AC)
Application Domain
Industrial
061017/9
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
copyright protected
Page 1/3
www.lem.com


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for CT0.4-P electronic component.


Information Total 3 Pages
Link URL [ Copy URL to Clipboard ]
Download [ CT0.4-P.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
CT0.4-PThe function is (CT0.1-P - CT0.4-P) Current Transducers. LEMLEM

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

CT0.     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search