5347
SMOKE DETECTOR
WITH INTERCONNECT AND TIMER
TIMER START 1
I/O 2
LOW-V SET 3
TIMER OUT 4
LED 5
+ SUPPLY 6 V DD
TIMING RES. 7
FEEDBACK 8
LOGIC
OSC. &
TIMING
HORN
DRIVER
16 GUARD 2
15 DETECT. IN
14 GUARD1
13
SENSITIVITY
SET
12 OSC. CAP.
11 HORN 2
10 HORN1
VSS 9 – SUPPLY
Dwg. PC-004
The A5347CA is a low-current, CMOS circuit providing all of the
required features for an ionization-type smoke detector. A networking
capability allows as many as 125 units to be interconnected so that if
any unit senses smoke, all units will sound an alarm. In addition,
special features are incorporated to facilitate alignment and test of the
finished smoke detector. This device is designed to comply with
Underwriters Laboratories Specification UL217.
The internal oscillator and timing circuitry keeps standby power to
a minimum by powering down the device for 1.66 seconds and sensing
smoke for only 10 ms. Every 24 on/off cycles, a check is made for low
battery condition. By substituting other types of sensors, or a switch
for the ionization detector, this very-low power device can be used in
numerous other battery-operated safety/security applications.
The A5347CA is supplied in a low-cost, 16-pin dual in-line plastic
package. It is rated for continuous operation over the temperature
range of 0°C to +50°C.
ABSOLUTE MAXIMUM RATINGS
(Voltages are referenced to VSS)
Supply Voltage Range,
VDD ................................ -0.5 V to +15 V
Input Voltage Range,
VIN ........................ -0.3 V to VDD + 0.3 V
Input Current, IIN ............................... 10 mA
Operating Temperature Range,
TA ..................................... 0°C to +50°C
Storage Temperature Range,
TS ............................... -55°C to +125°C
CAUTION: CMOS devices have input static
protection but are susceptible to damage when
exposed to extremely high static electrical
charges.
FEATURES
s Interconnect Up to 125 Detectors
s Piezoelectric Horn Driver
s Guard Outputs for Detector Input
s Pulse Testing for Low Battery
s Power-ON Reset
s Internal Timer & Control for Reduced Sensitivity
s Built-In Hysteresis Reduces False Triggering
Always order by complete part number: A5347CA .

1 page




5347 pdf
5347
SMOKE DETECTOR
with INTERCONNECT
and TIMER
Alarm Circuitry. If smoke is detected, the
oscillator period changes to 40 ms and the
horn is enabled. The horn output is typically
160 ms ON, 80 ms OFF. During the OFF
time, smoke is again checked and will inhibit
further alarm output if smoke is not sensed.
During smoke conditions the low battery
alarm is inhibited and the LED is driven at a
1 Hz rate.
Sensitivity Adjust. The detector sensitivity
to smoke is set internally by a voltage divider
connected between VDD and VSS. The
sensitivity can be externally adjusted to the
individual characteristics of the ionization
chamber by connecting a resistor between
pin 13 and VDD, or between pin 13 and VSS.
Low Battery. The low battery threshold is
set internally by a voltage divider connected
between VDD and VSS. The threshold can be
increased by connecting a resistor between
pin 3 and VDD. The threshold can be de-
creased by connecting a resistor between
pin 3 and VSS. The battery voltage level is
checked every 40 seconds during the 10 mA,
10 ms LED pulse. If an LED is not used, it
should be replaced with an equivalent
resistor (typically 500 to 1000 ) such that
the battery loading remains at 10 mA.
Timer. An internal timer is provided that can
be used in various configurations to allow for
a period of reduced smoke detector sensitiv-
ity (“hush”). When a high-to-low transition
occurs at pin 1, the internal timer is reset,
the timer mode enabled, and the circuit reset
to a no alarm condition. The LED will flash
at a 10 second rate. If the level of smoke is
increased such that the reduced sensitivity
level is reached, the device will go into the
alarm condition. The timer, however, will
continue to completion of the nominal 10-1/4
minute period (368 clock cycles). If the timer
mode is not used, pin 1 should be tied low.
NOTE 4
9V
TIMER
MODE
TYPICAL APPLICATION
200 k
TO
OTHER
UNITS
200
1
2
NOTE
3
330
3
4
5
LOGIC
OSC. &
TIMING
16
15
14
13
12
8.2 M
6 V DD
7
HORN
DRIVER
1 µF
8
11
10
VSS 9
0.1 µF
PUSH
TO
TEST
NOTE
1
NOTE 2
0.001 µF
Dwg. EC-005-2
NOTE 1: Use an external resistor to adjust sensitivity for a particular smoke
chamber.
NOTE 2: Select resistor to reduce sensitivity during timer mode.
NOTE 3:
A resistor to ground
voltage threshold.
or
VDD
may
be
added
to
this
pin
to
modify
low
battery
NOTE 4: Reverse battery protection must be supplied externally.
I/O. A connection is provided at pin 2 to allow multiple smoke detec-
tors to be commoned. If any single unit detects smoke (I/O is driven
high), all connected units will sound their associated horns after a
nominal 3 second delay. The LED is suppressed when an alarm is
signaled from an interconnected unit.
Testing. On power up, all internal counters are reset. Internal test
circuitry allows for low battery check by holding pins 8 and 12 low
during power up, then reducing VDD and monitoring HORN1 (pin 10).
All functional tests can be accelerated by driving pin 12 with a 2 kHz
square wave. The 10 ms strobe period must be maintained for proper
operation of the comparator circuitry.

5 Page










PáginasTotal 8 Páginas
PDF Descargar[ Datasheet 5347.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
5340-64BGS17F2.54mm (.100) Pitch QF-50 / Right Angle / Dual Row with Eject Levers / Shrouded Header / 64 CircuitsMolex Electronics
Molex Electronics
5347SMOKE DETECTOR WITH INTERCONNECT AND TIMERAllegro MicroSystems
Allegro MicroSystems
5348SMOKE DETECTOR WITH INTERCONNECT AND TIMERAllegro MicroSystems
Allegro MicroSystems
53481-1409HEADER CONNECTORMolex
Molex

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar