DataSheet39.com

What is CT19901?

This electronic component, produced by the manufacturer "Aeroflex Circuit Technology", performs the same function as "MIL-STD-1553B Remote Terminal/ Bus Controller/ or Passive Monitor Hybrid with Status Word Control".


CT19901 Datasheet PDF - Aeroflex Circuit Technology

Part Number CT19901
Description MIL-STD-1553B Remote Terminal/ Bus Controller/ or Passive Monitor Hybrid with Status Word Control
Manufacturers Aeroflex Circuit Technology 
Logo Aeroflex Circuit Technology Logo 


There is a preview and CT19901 download ( pdf file ) link at the bottom of this page.





Total 29 Pages



Preview 1 page

No Preview Available ! CT19901 datasheet, circuit

CT1990/1 Series
MIL-STD-1553B Remote Terminal, Bus Controller,
or Passive Monitor Hybrid with Status Word Control
Features
• Performs the Complete Dual-Redundant Remote Terminal, Bus Controller Protocol
and Passive Monitor Functions of MIL-STD-1553B
• Automated Self-Test Functions
• Allows setting of the Message Error Bit on illegal commands
• Provides programmable control over Terminal Flag and Subsystem Flag Status Bits
• MIL-PRF-38534 Compliant Circuits Available
• 50 mw Typical Power Consumption
• Small Size
• Available in Ceramic Plug-in Package Configuration
• Compatible with all ACT Driver/Receiver Units
CIRCUIT TECHNOLOGY
• 5V DC Operation
• Full Military (-55°C to +125°C) Temperature Range
• DESC SMD# 5962–94775: Released CT1990, Pending CT1991
1
General Description
The CT1990/1 Series is a monolithic implementation of the MIL-STD-1553B Bus Controller, Remote
Terminal and Passive Monitor functions. All protocol functions of MIL-STD-1553B are incorporated and a
number of options are included to improve flexibility. These features include programming of the status
word, illegalizing specific commands and an independent loop back self-test which is initiated by the
subsystem. This unit is directly compatible with all transceivers and microprocessor interfaces such as the
CT1611 and CT1800 produced by Aeroflex Incorporated.
Block Diagram (With Transformers)
Encoder
Interface
Unit
Sub Address
&
Word Count
Outputs
BUS "0"
T/R
Hybrid
BUS "1"
T/R
Hybrid
Driver
Select
&
Enable
Decoder
"O"
Decoder
"1"
Status
Word
Control
Internal
Highway
Control
Program
Inputs
Discrete
Outputs
Control
Inputs
Terminal
Address
Inputs
CT1990/1
eroflex Circuit Technology – Data Bus Modules For The Future © SCD1990 REV B 8/21/00

line_dark_gray
CT19901 equivalent
Synchronize Mode Commands
Once the RT has validated the command word and checked for the correct address, the SYNC line is set low.
The signal WC4 will be set low for a Synchronize mode command (See Figure 16), and high for a Synchronize
with data word mode command (See Figure 15). In a Synchronize with data word mode command, SYNC
remains low during the time that the data word is received. Once the data word has been validated, it is passed
to the subsystem on the internal highway IH08-IH715 in two bytes using IUSTB as a strobe signal and H/L as
the byte indicator (high byte first followed by low byte). SYNC being low should be used on the enable to allow
IUSTB to clock synchronize mode data to the subsystem.
If the subsystem does not need to implement either of these mode commands, the SYNC signal can be ignored,
since the RT requires no response from the subsystem.
Transmit Vector Word Mode Command
Figure 14 illustrates the relevant signal timings for an RT receiving a valid Transmit Vector Word mode
command. The RT requests data by setting VECTEN low. The subsystem should use H/L to enable first the high
byte and then the low byte of the Vector word onto the internal highway IH08-IH715.
It should be noted that the RT expects the Vector word contents to be already prepared in a latch ready for
enabling onto the internal highway when VECTEN goes low. If the subsystem has not been designed to handle
the Vector word mode command, it will be the fault of the Bus Controller if the RT receives such a command.
Since the subsystem is not required to acknowledge the mode command, the RT will not be affected in any way
by Vector word circuitry not being implemented in the subsystem. It will however transmit a data word as the
Vector word, but this word will have no meaning.
Reset Mode Command
Figure 8 shows the relevant signal timings for an RT receiving a valid reset mode command. Once the command
word has been fully validated and serviced, the RESET signal is pulsed low. This signal may be used as a reset
function for subsystem interface circuitry.
Dynamic Bus Allocation
This mode command is intended for use with a terminal which has the capability of configuring itself into a bus
controller on command from the bus. The line DBCREQ cannot go true unless the DBCACC line was true at the
time of the valid command, i.e. tied low. For terminals acting only as RTs, the signal DBCACC should be tied
high (inactive), and the signal DBCREQ should be ignored and left unconnected.
Use of the Busy Status Bit
The Busy Bit is used by the subsystem to indicate that it is not ready to handle data transfers either to or from
the RT.
The RT sets the bit to logic one if the BUSY line from the subsystem is active low at the time of the second falling
edge of INCLK after INCMD goes low. This is shown in Figure 13. Once the Busy bit is set, the RT will stop all
receive and transmit data word transfers to and from the subsystem. The data transfers in the Synchronize with
data word and Transmit Vector word mode commands are not affected by the Busy bit and will take place even if
it has been set.
It should be noted that a minimum of 0.5 µs subaddress decoding time is given to the subsystem before setting
of status bits. This allows the subsystem to selectively set the Busy bit if for instance one subaddress is busy but
others are ready. This option will prove useful when an RT is interfacing with multiple subsystems.
Use of the Service Request Status Bit
The Service Request bit is used by the subsystem to indicate to the Bus Controller that an asynchronous
service is requested.
The timing of the setting of this bit is the same as the Busy bit and is shown in Figure 13. Use of SERVREQ has
no effect on the RT apart from setting the Service Request bit.
It should be noted that certain mode commands require that the last status word be transmitted by the RT
Aeroflex Circuit Technology
5 SCDCT1990 REV B 8/21/00 Plainview NY (516) 694-6700


line_dark_gray

Preview 5 Page


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for CT19901 electronic component.


Information Total 29 Pages
Link URL [ Copy URL to Clipboard ]
Download [ CT19901.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
CT1990The function is MIL-STD-1553B Remote Terminal / BUS Controller or Passive Monitor Hybrid. Aeroflex Circuit TechnologyAeroflex Circuit Technology
CT19901The function is MIL-STD-1553B Remote Terminal/ Bus Controller/ or Passive Monitor Hybrid with Status Word Control. Aeroflex Circuit TechnologyAeroflex Circuit Technology

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

CT19     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search