Descripción Axial Cemented Fusible Wirewound Safety Resistors
Fabricantes Vishay 
Logotipo Vishay Logotipo



Hay una vista previa y un enlace de descarga de AC03-CS (archivo pdf) en la parte inferior de esta página.


Total 9 Páginas

No Preview Available ! AC03-CS Hoja de datos, Descripción, Manual

www.vishay.com
AC01-CS, AC03-CS, AC05-CS
Vishay Draloric
Axial Cemented Fusible Wirewound Safety Resistors
FEATURES
• UL1412 recognized; UL file no. E362452
(AC03-CS and AC05-CS only)
• Surge voltage handling capability (up to 6 kV)
(1.2 / 50 μs pulse in IEC 61000-4-5)
• Silent and safe fusing
• Material categorization:
for definitions of compliance please see
www.vishay.com/doc?99912
ACxx-CS wirewound safety resistor series is designed to be
used as fusible safety resistor (or, AC mains input resistors).
The resistor fuses “without a bang” when AC mains voltage
is applied. At the same time, it acts as an in-rush current
limiting resistor for the normal operation. The specially
developed lacquer coating has superior thermal and
electrical insulating properties. This allows designers to
more easily meet the requirements of safety approval, whilst
eliminating the need to put additional fuses in series with the
input resistor.
APPLICATIONS
• Energy meters
• LED drivers
• White goods
• Power supplies
TECHNICAL SPECIFICATIONS
DESCRIPTION
AC01-CS
Resistance range (1)
3 to 100
Resistance tolerance
Temperature coefficient
Rated dissipation, P40
Rated dissipation, P70
Operating voltage, Umax. AC/DC
Operating temperature range
1.1 W
1W
Max. resistance change for 116 % of P70,
R max., after 1000 h:
Note
• Resistance value to be selected for ± 5 % from E24 series.
AC03-CS
4.7 to 100
±5%
± 200 ppm/K
3W
2.5 W
PxR
-40 °C to 200 °C
± (5 % R + 0.1 )
AC05-CS
10 to 100
5W
4.5 W
Revision: 12-Jul-16
1 Document Number: 28909
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000

1 page




AC03-CS pdf
www.vishay.com
FUNCTIONAL PERFORMANCE
Pulse energy curve defined against the offered ohmic range.
8
7
6
5
4
3
2
1
AC01-CS, AC03-CS, AC05-CS
Vishay Draloric
0 10 20 30 40 50 60 70 80 90 100
RESISTANCE VALUE IN Ω
PULSE ENERGY CURVE FOR AC01-CS
(1.2 / 50 μs; 10 pulses at 30 s interval)
30
25
20
15
10
5
0 10 20 30 40 50 60 70 80 90 100
RESISTANCE VALUE IN Ω
PULSE ENERGY CURVE FOR AC03-CS
(1.2 / 50 μs; 10 pulses at 30 s interval)
60
50
40
30
20
10
0
10 22 33 39 47 56 62 68 75 82 91 100
RESISTANCE VALUE (Ω)
PULSE ENERGY CURVE FOR AC05-CS
(1.2 / 50 μs; 10 pulses at 30 s interval)
Revision: 12-Jul-16
5 Document Number: 28909
For technical questions, contact: [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000

5 Page










PáginasTotal 9 Páginas
PDF Descargar[ Datasheet AC03-CS.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
AC03-CSAxial Cemented Fusible Wirewound Safety ResistorsVishay
Vishay

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar