4 Absolute Maximum Ratings
Supply voltage range, VCC (see Note1)……………………………………………………..-0.3V to 4V
Output voltage range, VO…..……………….…………………………………………………-0.3V to VCC +0.3V
Input voltage range, VI……………………………….……………………….…………………………-0.3V to Vcc +0.3V
Storage temperature range, Tstg……………………………………………………………-65°C to 150°C
Lead temperature 1, 6 mm (1/16 inch) from case for 10 seconds………………………260°C
Junction Temperature…………………………………………………………………………150°C
# Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to this device. These are stress
ratings only. Functional operation of this device at these or any other conditions above those indicated in the operational sections of
this specification is not implied or intended. Exposure to the absolute maximum rating conditions for extended periods may affect
device reliability.
4.1 Recommended Operating Conditions
Symbol
Parameter
VCC Supply voltage
VIH High-level input voltage
VIL Low-level input voltage
ZL Differential load impedance
TA Operating free-air temperature
Min.
3.0
2
90
0
Nom.
3.3
100
Max.
3.6
0.8
110
70
Unit
V
V
V
Ω
°C
4.2 Timing requirements
Symbol
Parameter
Min. Nom. Max. Unit
TC Cycle time, input clock
11.8 40 ns
tW Pulse duration, high-level input clock
0.4tc
0.6tc ns
tT Transition,
5 ns
tsu Setup time, data, TD0 - TD27 valid before CLKIN↑or CLKIN ↓ (See Figure 1) 5
ns
th Hold time, data, , TD0 - TD27 valid after CLKIN↑or CLKIN ↓ (See Figure 1)
2.5
Note: th is measured under the conditions of input clock jitter of 1.9ns at 65MHz.
ns
5