SA9604/5 APPLICATION NOTE
PM9604/5AP
THREE PHASE POWER/ENERGY METERING MODULE
FOR SPI BUS AND PULSE OUTPUT DEVICES
FEATURES
s Module used for both SA9604A and s Uses current transformers for current
SA9605A evaluation
sensing
s Meets the accuracy requirements for s Protection against ESD
Class 1 AC Watt hour meters
s Unused connection pads allows the
s Operates over a wide temperature
module to be customised
range
DESCRIPTION
This innovative power/energy module allows evaluation of both the SA9604A and
SA9605A, members of the SAMES three phase metering I.C. family.
It is advised that the relevant data sheet for the device under evaluation be read in
conjunction with this Application Note.
The output of this innovative universal three phase power/energy metering circuit is
ideally suited for energy calculations in applications using a µ-controller (SA9604A and
SA9605A) or mechanical counter (SA9605A).
On the left hand side of the board, next to the 25-way D-type connector, the array of
unused solder pads allow the user to customise the module. This section of the board
may be used to access the opto-coupler isolated output signals. Such components as
counters and LEDs may be added to this area to allow the user evaluation of a design
using the SA9604A or SA9605A.
CARE MUST BE TAKEN WHEN CONNECTING ADDITIONAL COMPONENTS TO
THE BOARD AS DANGEROUS VOLTAGE LEVELS EXIST IN SOME AREAS.
BLOCK DIAGRAM
LINE 1
LINE 2
LINE 3
NEUTRAL
PHASE 1
PHASE 2
PHASE 3
SIGNA L
C O N D IT IO N IN G
+ 2.5V
0
- 2.5V
S A 9604/5A
J4
FOUT 1
FOUT 2
SK3
O
P
T
FOUT X (SA9605A)
O
C
O
U
P
L
E
DIR
R
SK2
O
P
T
O
(SA 9604A)
C
O
U
P
L
E
R
25-WAY D-TYPE - FEMALE
7205
PDS038-SA9604/5-001
REV.B
1/14
18-06-98
|
|
PM9604/5AP
6. Jumper Configurations
The jumper configufations required for the two devices types are shown below:
JUMPER POSITION
JP1 1 - 2
JP2 1 - 2
JP3 1 - 2
JP4 1 - 2
2-3
3-4
JP5 1 - 2
2-3
JP6 1 - 2
2-3
JP7 1 - 2
SA9604A
Insert
Insert
Insert
Remove
Remove
Insert (SCK)
Remove
Insert (CS)
Remove
Insert (DI)
Remove
SA9605A
Insert
Insert
Insert
Insert (FOUT1)
Insert (FOUT2)
Remove
Insert (PGM1=1)
Remove (PGM1=0)
Insert (PGM0=1)
Remove (PGM0=0)
Insert
NOTES
Note 1
Note 2
Note 3
Note 3
Note 1:
Note 2:
Note 3:
The removal of the link on the current sensor input must only be
performed during calibration.
Only one of the two output pulse signals on the SA9605A may be
selected at any one time using this module. In a users application both
of these signals may be used.
The SA9605A I.C. has on-board pull-down resistors, pull-up connection
to VDD is, therefore, the only connection which must be catered for.
sames
5/14
Preview 5 Page |
Part DetailsOn this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for PM9604AP electronic component. |
Information | Total 14 Pages | |
Link URL | [ Copy URL to Clipboard ] | |
Download | [ PM9604AP.PDF Datasheet ] |
Share Link :
Electronic Components Distributor
An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists. |
SparkFun Electronics | Allied Electronics | DigiKey Electronics | Arrow Electronics |
Mouser Electronics | Adafruit | Newark | Chip One Stop |
Featured Datasheets
Part Number | Description | MFRS |
PM9604AP | The function is THREE PHASE POWER/ENERGY METERING MODULE. Sames | |
Semiconductors commonly used in industry:
1N4148 |  
BAW56 |
1N5400 |
NE555 | | ||
Quick jump to:
PM96
1N4
2N2
2SA
2SC
74H
BC
HCF
IRF
KA |